SR50AH-L Heated Sonic Distance Sensor
Rugged, heated acoustic distance sensor
Prevents ice from coating the transducer
meteorología aplicaciones agua aplicaciones energía aplicaciones flujo gas y turbulencia aplicaciones infraestructuras aplicaciones suelo aplicaciones

Resumen

The SR50AH Heated Sonic Distance Sensor provides a non-contact method for determining snow depth. It determines depth by emitting an ultrasonic pulse and then measuring the elapsed time between the emission and return of the pulse. An air temperature measurement is required to correct for variations of the speed of sound in air. The SR50AH includes an integrated heater that prevents ice and rime from coating the transducer.

Leer más

Ventajas y características

  • Non-contact method for determining snow depth
  • Integrated transducer heater; rugged enough for rime and ice environments
  • Wide operating temperature range
  • User-selectable options for output
  • Uses a multiple echo processing algorithm to help ensure measurement reliability
  • Compatible with most Campbell Scientific data loggers

Imágenes

Descripción detallada

The SR50AH was designed to meet the stringent requirements of measuring depths and uses a multiple echo processing algorithm to help ensure measurement reliability. The addition of a heating element around the transducer prevents ice and rime from coating the transducer with minimal power requirements.

SDI-12, RS-232, and RS-485 output options are available for measuring the SR50AH. Campbell Scientific’s MD485 interface can be used to connect one or more SR50AH sensors in RS-485 mode to an RS-232 device. This can be useful for sensors that require lead lengths that exceed the limits of either RS-232 or SDI-12 communications.


Especificaciones

Measurement Time < 1.0 s
Output Options SDI-12 version 1.3, RS-232, RS-485 (output options selected by configuring internal jumpers)
Baud Rates 1200 to 38400 bps (RS-232, RS-485 modes)
Power Requirements 9 to 18 Vdc (typically powered by data logger’s 12 Vdc power supply)
Measurement Range 0.5 to 10 m (1.6 to 32.8 ft)
Beam Acceptance ~30°
Resolution 0.25 mm (0.01 in.)
Accuracy ±1 cm (0.4 in.) or 0.4% of distance to target (whichever is greatest). Requires external temperature compensation.
Temperature Accuracy
  • ±0.2° (at 0° to 50°C)
  • ±0.75° (at -45° to 0°C)
Operating Temperature Range -45° to +50°C
Compliance CE compliant
Length 10.1 cm (4.0 in.)
Diameter 7.5 cm (3 in.)
Cable Weight 250 g (8.2 oz) for a 4.57 m (15 ft) cable

Maximum Cable Length

-NOTE- Cable lengths greater than 60 m require a heavier gage wire if the power supply drops below 11 Vdc.
SDI-12 60 m (200 ft)
RS-232 60 m (200 ft)
Baud rates ≤ 9600 bps
RS-485 300 m (984 ft)

Heater

Heater Resistance 75 ohm
Nominal Operating Voltage 12 V (ac or dc)
Use a properly conditioned low-noise power source. A noisy power source will affect operation of the sensor.
Maximum Rated Wattage 3 W
Maximum Rated Voltage 15 V (ac or dc)
Maximum Operating Temperature 25°C
Turn the heater power off at temperatures above 25°C. This prevents damage to the sensor and reduces power consumption.

Compatibilidad

Nota: lo siguiente muestra información de compatibilidad notable. No es una lista de todos los productos compatibles.

Dataloggers

Producto Compatible Nota
CR1000 (retired) SDI-12 and RS-232. For RS-485, requires an MD485 interface or similar RS-485 to RS-232 interface.
CR1000X SDI-12 and RS-232. For RS-485, requires an MD485 interface or similar RS-485 to RS-232 interface.
CR300 (retired) SDI-12 and RS-232. For RS-485, requires an MD485 interface or similar RS-485 to RS-232 interface.
CR3000 (retired) SDI-12 and RS-232. For RS-485, requires an MD485 interface or similar RS-485 to RS-232 interface.
CR310 SDI-12 and RS-232. For RS-485, requires an MD485 interface or similar RS-485 to RS-232 interface.
CR350 SDI-12 and RS-232. For RS-485, requires an MD485 interface or similar RS-485 to RS-232 interface.
CR6 SDI-12, RS-232, and RS-485
CR800 (retired) SDI-12 and RS-232. For RS-485, requires an MD485 interface or similar RS-485 to RS-232 interface.
CR850 (retired) SDI-12 and RS-232. For RS-485, requires an MD485 interface or similar RS-485 to RS-232 interface.

Miscelaneo

Producto Compatible Nota
GRANITE 6 SDI-12 and RS-232. For RS-485, requires an MD485 interface or similar RS-485 to RS-232 interface.

Información de compatibilidad adicional

Data Logger Considerations

One single-ended channel per probe is required; an excitation channel can be shared by several probes.