The Granite™6 DAQ is a powerful core component for your complete data-acquisition system. The Granite 6 provides fast communication, low power requirements, built-in USB and Wi-Fi, modular design, and high analog input accuracy and resolution. It uses universal (U) terminals to allow a connection to virtually any sensor—analog, digital, or smart. The multipurpose DAQ is also capable of measuring static vibrating wire measurements.

Learn about our patented VSPECT® spectral-analysis technology at our VSPECT Essentials web resource.

The dynamic vibrating wire measurement technique is protected under U.S. Patent No. 8,671,758, and the vibrating wire spectral-analysis technology (VSPECT) is protected under U.S. Patent No. 7,779,690.

Leer más

Ventajas y características

  • Funcionamiento en condiciones ambientales extremas de -40° a +70°C
  • Fácil conexión a PC por USB, Wi-Fi, EtherNet
  • Terminales universales configurables para señales analógicas y digitales, de entrada y salida
  • Compatible con medidas estáticas de cuerda vibrante, mediante tecnología análisis espectral VSPECT™ patentada por Campbell Scientific
  • Líder en la industria para satisfacer necesidades de medidas de alta resolución.
  • La tecnología host USB proporciona memoria adicional en aplicaciones que usan muchos datos

Imágenes

Descripción detallada

El Granite 6 tiene una versatilidad extrema de medición, con múltiples opciones en comunicaciones, convierte las señales eléctricas en unidades de ingeniería, realiza cálculos, genera alarmas y controla dispositivos externos. Los datos se almacenan en la memoria interna no volátil, que se pueden descargar mediante acceso directo o remoto. El Granite 6 genera tablas de datos basadas en tiempo real o controladas por eventos. Incluye funciones matemáticas y estadísticas de alto nivel como promedios, desviaciones estándar, rainflow histograms, etc.


Preguntas frecuentes

Número de FAQs relacionadas con GRANITE 6: 1

  1. The CPI bus speed is adjustable in your CRBasic data logger program. Use the CPISpeed() instruction in your CRBasic program to adjust the CPI bus bandwidth to meet the following maximum combined (total) Ethernet cable lengths:

    • 1000 kB/s for maximum combined Ethernet cable lengths of 15.2 m (50.0 ft)
    • 500 kB/s for maximum combined Ethernet cable lengths of 61 m (200 ft)
    • 250 kB/s for maximum combined Ethernet cable lengths of 152.4 m (500 ft)

Especificaciones

-NOTE- Additional specifications are listed in the GRANITE 6 Specifications.
Pulse Counters 12 (U1 to U12)
Voltage Excitation Terminals 12 (U1 to U12)
Universal Inputs 12 individually configured inputs for analog or digital functions
Case Material Stainless steel 304 and aluminum 6061
Operating Temperature Range
  • -40° to +70°C (standard)
  • Non-condensing environment
Communications Ports
  • Ethernet
  • USB Micro B
  • USB host
  • CS I/O
  • 0 to 5 V serial
  • SDI-12
  • RS-485
  • RS-422
  • CPI/RS-232
Data Storage Ports
  • microSD
  • USB host
Digital I/O 16 terminals (C1 to C4, U1 to U12) configurable for digital input and output. Terminals are configurable in pairs for 5 V or 3.3 V logic for some functions.
Analog Voltage Accuracy Accuracy specifications do not include sensor or measurement noise.
Analog Voltage Accuracy
  • ±(0.04% of measurement + offset) at 0° to 40°C
  • ±(0.06% of measurement + offset) at -40° to +70°C
ADC 24-bit
Power Requirements
  • 16 to 32 Vdc for charger input (CHG)
  • 10 to 16 Vdc for battery input (BAT)
Real-Time Clock Accuracy ±3 min. per year (optional GPS correction to ±10 µs; 5.7 ppm)
Internet Protocols Ethernet, PPP, RNDIS, ICMP/Ping, Auto-IP (APIPA), IPv4, IPv6, UDP, TCP, TLS (v1.2), DNS, DHCP, SLAAC, Telnet, HTTP(S), SFTP, FTP(S), POP3/TLS, NTP, SMTP/TLS, SNMPv3, CS I/O IP
Communication Protocols CPI, PakBus, PakBus Encryption, SDM, SDI-12, Modbus RTU / ASCII / TCP, DNP3, custom user definable over serial, UDP, NTCIP, NMEA 0183, I2C, SPI
Warranty
  • 3 years standard (against defects in materials and workmanship)
  • Optional: An additional 2 years (against defects in materials and workmanship), bringing the total to 5 years
Battery-backed SRAM for CPU Usage & Final Storage 4 MB
Data Storage 4 MB SRAM + 72 MB flash (Storage expansion of up to 16 GB with removable microSD flash memory card.)
Idle Current Drain, Average
  • Assumes 12 Vdc on BAT terminals; add 2 mA if using CHG terminals.
  • < 1 mA
Active Current Drain, Average
  • Assumes 12 Vdc on BAT terminals; add 2 mA if using CHG terminals.
  • 3 mA (1 Hz scan)
  • 67 mA (20 Hz scan)
Static Vibrating Wire Measurements Supported
Dimensions 21.4 x 12.0 x 5.0 cm (8.4 x 4.7 x 2.0 in.)
Additional clearance required for cables and leads.
Weight 0.86 kg (1.9 lb)

Compatibilidad

Nota: lo siguiente muestra información de compatibilidad notable. No es una lista de todos los productos compatibles.

Dataloggers

Producto Compatible Nota
CR1000X
CR6

Medida y Control

Producto Compatible Nota
CDM-A108
CDM-A116 (retired)
CDM-VW300 (retired)
CDM-VW305 (retired)
Granite Temp 120 Requires OS version 1 or greater.
GRANITE VOLT 108
GRANITE VOLT 116
Granite VWire 305

Software

Producto Compatible Nota
DevConfig
LoggerNet
PC200 (retired)
PC400
RTDAQ

Miscelaneo

Producto Compatible Nota
GRANITE Chassis

Videos & Tutoriales

Descargas

GRANITE 6 OS v.3.01 (6.69 MB) 26-09-2024

This download is for the GRANITE 6 datalogger. Execution of this download places the Operating System file(.obj) on your computer. It also updates the CRBasic Editor compiler and support files. 

Why Update? UID (unique identifier) is now utilized for enhancing security along with other features and bug fixes. With this OS update it is recommended that you also update the Device Configuration Utility to the most recent version so that new datalogger features are available in the utility.  

Note/Warning: Campbell Scientific always recommends updating operating systems on site if possible. When remote updates are required, it is recommended that you implement the necessary precautions to handle unexpected OS upload complications. All datalogger settings should be retained when updated remotely. If you choose to roll back to a previous operating system, the datalogger settings will be reset to default.

Watch the Video Tutorial: Sending an OS to a Local Datalogger.

Historial revisiones

GRANITE 6 Web Browser Interface v.1.2 (784 KB) 13-09-2024

Standard Datalogger Web Browser Interface

Use this download to update the dataloggers web browser interface.

To install this file, send it to the datalogger using file control found in the Device Configuration Utility or file control found in LoggerNet.

This interface is recommended for fast IP interfaces like Ethernet and WiFi. It does NOT perform well over slow communications mediums like cellular.

Note: This is NOT for system dataloggers that have custom interfaces like the SunSentry, Hydro-Link, Alert205, and MeteoPV.


Granite 6 WiFi OS Update v.5.01 (1.33 MB) 07-10-2020

Granite 6 Wi-Fi OS update. This download includes the Wi-Fi OS.

Historial revisiones

CPI Calculator v.1.0 (2.49 MB) 06-07-2016

The CPI Calculator is a downloadable Microsoft Excel spreadsheet used to estimate the usage and capacity of a CPI network.  The calculator provides an overview on CPI devices including the CDM-A108, CDM-A116, CDM-VW300, CDM-VW305, and the CSAT3B.  The calculator can also estimate the measurement speed of the CDM-A108 and CDM-A116 based on the number of channels and measurement parameters.

 

The CPI Calculator is an estimation tool and will help you better understand and design CPI networks by considering the following:

  1. What is the capability of each CDM or CPI device
  2. What is the CPI network capacity
  3. How much of the CPI capacity are the CDMs or CPI devices using

 


VWire 305 program example v.1 (2 KB) 16-01-2020

Program to read 20 Hz dynamic data from two VWire 305 analyzers measuring eight channels each.


Custom Menu Example Program for Connections Video v.1 (1 KB) 26-03-2024

This program demonstrates creating a custom menu for data logger displays and corresponds to the Campbell Connections video: Creating Custom Menus in CRBasic for a Data Logger Display