Disponibilidad limitada ›
Este producto sufre disponibilidad limitada. Será sustituido por: MD485. En caso de que quedara descatalogado, podrían seguir estando disponibles accesorios, recambios, u otros servicios.
MD9 Coax Multidrop Interface

Resumen

Effective 1 January 2004, the MD9 Multidrop Interface was generally replaced for new multidrop applications by the MD485 Multidrop Interface. However, the MD9 remains available for customers with existing MD9 networks.

The MD9 Multidrop Interface links a computer to as many as 200 dataloggers over a single coaxial cable. Each datalogger in the network is connected to an MD9 that has a unique, user-assigned address. Communication between the computer and a specific datalogger is routed through the MD9’s address allowing the rest of the network to remain in quiescent mode. Total coaxial cable length can be up to three miles; each MD9 in the network slightly reduces the maximum transmission distance.

Leer más

Imágenes

Descripción detallada

Effective 1 January 2004, the MD9 Multidrop Interface was generally replaced for new multidrop applications by the MD485 Multidrop Interface. The MD9 remains available for customers who have MD9 networks currently deployed in the field. MD9s and MD485s can NOT be used in the same network.

The MD9 Multidrop Interface links a central computer to up to 200 data loggers on a single coaxial cable. Total cable length can be up to 3 miles. At least two MD9s are required within a network.

Productos similares


Preguntas frecuentes

Número de FAQs relacionadas con MD9: 1

  1. Yes, but only if all the other dataloggers are PakBus devices, such as the CR800, CR850, and CR1000.

Especificaciones

Baud Rates 9600, 1200, 300 (hardware-selectable)
Current Drain
  • 1.2 mA (quiescent)
  • 80.0 mA (active)
Operating Voltage 5 Vdc (from the PS150 or SC532(A) interface)
Carrier Frequency 1.2 MHz
Rango temperatura funcionamiento
  • -25° to +50°C (standard)
  • -55° to +85°C (extended)
Dimensiones 16.2 x 8.8 x 3.0 cm (6.4 x 3.5 x 1.2 in.) including connectors
Peso 227 g (8 oz)

Compatibilidad

Nota: lo siguiente muestra información de compatibilidad notable. No es una lista de todos los productos compatibles.

Dataloggers

Producto Compatible Nota
CR1000 (retired) Requires LoggerNet 4.2 or higher.
CR200X (retired)
CR216X (retired)
CR3000 (retired) Requires LoggerNet 4.2 or higher.
CR5000 (retired)
CR800 (retired) Requires LoggerNet 4.2 or higher.
CR850 (retired) Requires LoggerNet 4.2 or higher.
CR9000X (retired)

Miscelaneo

Producto Compatible Nota
21X (retired) The 21X should have a serial number of 6195 or higher (others require factory modification and an RMA).
CR10 (retired)
CR10X (retired) The -PB versions of the CR10X requires LoggerNet 4.2 or higher.
CR23X (retired) The -PB versions of the CR23X requires LoggerNet 4.2 or higher.
CR500 (retired)
CR510 (retired) The -PB versions of the CR510 requires LoggerNet 4.2 or higher.
CR9000 (retired)

Documentos

Casos de aplicación

San Diego: Slope Monitoring
The North County Transit District (NCTD) of San Diego County, California, determined that three segments......leer más
Australia: OzFace--CO2 and Climate Change
An experimental facility (OzFace) has been established in Townsville, Australia to examine the impacts of......leer más