Imagen no disponible
Services Available |
---|
Current version: 4.0
The Baler software connects to the LoggerNet Server from a remote PC and creates bales of data at regular intervals based on the date/time stamps in the data. Baler's primary function is to access data on the LoggerNet server, bundle appropriate data, and store the data on the client computer.
Leer másThe Baler client is ideal for applications in which the data will be imported to a database or a third-party analysis program.
Specifically, the Baler client:
Unlike LoggerNetData and RTMCRT, Baler does not include functionality to view or interact with the data. The datafile names are based on the datalogger and table names. Multiple instances of Baler can be run with separate working directories if data must be baled according to different conditions.
Número de FAQs relacionadas con BALER: 10
Expandir todoDesplegar todo
Yes, but a file transfer or copy program is needed. Baler includes an option to run a program 30 seconds after a baling event occurs. A batch file can be constructed that calls a program to move the contents of the folder with the baled files to a location on a Unix server. The batch file calls a program such as SCP and specifies the parameters of the command.
For more details, review the “Advanced Options” section of the Baler Instruction Manual.
The current version of Baler can be found in the Downloads section of the Baler product page. Note that Baler version 2.2 is required to be installed for this upgrade to work.
The destination folder for baled files is created during setup. If the program is not running under an account that has permissions for the destination folder, Baler displays one or both of these messages. To resolve this error, either run Baler under an administrator account, or set the permissions on the folder so that the account has full control.
Baler program configuration information is stored in the baler.ini file that is found, in a default installation, in the C:\Campbellsci\Baler\sys\inifiles folder. If this file is renamed or moved, Baler starts up as if it was freshly installed.
The same thing can be accomplished by starting up the program with a new working directory using the /WorkDir command line parameter. For more details, review the “Command Line Options” section of the Baler Instruction Manual.
Currently, Campbell Scientific only distributes software on media. The possessor of the media is viewed as the holder of the license. If the CD is lost, a new license would have to be purchased.
Baler 2.2 was developed before the release of the CR800 and, therefore, does not work with it.The latest version of Baler does work with the CR800 and can be found in the Downloads section of the Baler product page.
Note: As newer versions of Baler are released, upgrades to older versions may not work. The notes associated with the upgrade or patch indicate which previous version needs to be installed before installing the upgrade.
Baler is a LoggerNet client (purchased separately from LoggerNet) that uses the records going into the LoggerNet data cache. Baler separates or “bales” files into user-defined chunks based on time and gives them a unique file name. This process is fully automated. For example, Baler can be set up to store files hourly, every 4 hours, or every 24 hours. The file name reflects the time stamp of the first record in the file. Baler does not insert a time-stamp string into the data file, but the file name indicates the time stamp. Because they are separate, the files created by Baler do not affect the other *.dat files created by LoggerNet.
Check that the new table has been selected on the Baler Baling Setup tab. (Selected tables should appear in the Selected Tables field on the right side of the screen.) If the new table has not been selected, click the Pause Baling button, click the desired table, and click the right-facing arrow to add it to the list. Then click the Enable Baling button to restart the baling process.
After restarting, Baler creates bales of the specified interval size for all of the data that currently exists in the LoggerNet cache and has not been baled yet.
If the table has been selected, but no data files are being created, check that the table is enabled for scheduled collection on the Table Status tab in Baler. If the Enable column of the table displays No, there is an issue in the LoggerNet Setup screen.
On the LoggerNet Setup screen, on the datalogger Schedule tab, ensure that the Scheduled Collection Enabled checkbox is selected. Also, ensure that the data collection interval is set so that data is collected into the LoggerNet cache. In addition, on the Data Files tab, ensure that the table has the Included for Data Collection checkbox selected. Baler only bales data that has been collected into the LoggerNet data cache.
If everything appears correct in the LoggerNet Setup screen, start the LoggerNet Status Monitor, and ensure that the Pause Schedule checkbox isn’t selected. (Selecting that checkbox stops all scheduled data collection for all of the dataloggers.) On the Status Monitor page, it is possible to check when the data was last collected for the datalogger and when data will next be collected.
No. LNDB works independently of Baler.
Baler does have file format options for storing the data. These are
TOACI1 (table to ASCII 1 format), TOA5 (table to ASCII 5 format), TOB1
(table to binary format), or CSV (comma separated values).TOACI1 example:
"TOACI1", "CR1000_2", "Data1Hr""TMSTAMP", "RECNBR", "Batt_Volt_Min", "Panel_TempF_Avg", "AirTempF_Avg", "RH", "WSData_S_WVT", "WSData_D1_WVT", "WSData_SD1_WVT", "WS_mph_Min", "WS_mph_Max", "WindDir_SMM", "SlrW_Avg", "Rain_in_Tot", "BP_inHg_Avg", "FuelM_Avg", " FuelT_F_Avg", "TdewF_Avg"
"2008-03-14
16:00:00" , 22, 13.07, 73.8, 72.98, 20.72, 0, 0, 0, 0, 0, -0.097, 0.021, 0, 26.34, 7999, 7999, 29.37
TOA5 example:
"TOA5", "CR1000_2", "CR1000", "1243", "CR1000.Std.14.16", "CPU:RAWS-F_V1-fixedGOES_Frank_H_Test.CR1", "52455", "Data1Hr""TIMESTAMP", "RECORD", "Batt_Volt_Min", "Panel_TempF_Avg", "AirTempF_Avg", "RH", "WSData_S_WVT", "WSData_D1_WVT", "WSData_SD1_WVT", "WS_mph_Min", "WS_mph_Max", "WindDir_SMM", "SlrW_Avg", "Rain_in_Tot", "BP_inHg_Avg", "FuelM_Avg", "FuelT_F_Avg", "TdewF_Avg"
"TS", "RN", "Volts", "Deg F", "Deg
F", "%", "miles/hour", "Deg", "Deg", "miles/hour", "miles/hour", "Degrees", "W/m²", "inch", "In
of Hg", "%", "Deg F", "Deg F"
"", "", "Min", "Avg", "Avg", "Smp", "WVc", "WVc", "WVc", "Min", "Max", "SMM", "Avg", "Tot", "Avg", "Avg", "Avg", "Avg"
"2008-03-14
16:00:00", 22, 13.07, 73.8, 72.98, 20.72, 0, 0, 0, 0, 0, -0.097, 0.021, 0, 26.34, "NAN", "NAN", 29.37
TOB1 example:
"TOB1", "CR1000_2", "CR1000", "1243", "CR1000.Std.14.16", "CPU:RAWS-F_V1-fixedGOES_Frank_H_Test.CR1", "52455", "Data1Hr"
"SECONDS", "NANOSECONDS", "RECORD", "Batt_Volt_Min", "Panel_TempF_Avg", "AirTempF_Avg", "RH", "WSData_S_WVT", "WSData_D1_WVT", "WSData_SD1_WVT", "WS_mph_Min", "WS_mph_Max", "WindDir_SMM", "SlrW_Avg", "Rain_in_Tot", "BP_inHg_Avg", "FuelM_Avg", "FuelT_F_Avg", "TdewF_Avg"
"SECONDS", "NANOSECONDS", "RN", "Volts", "Deg F", "Deg
F", "%", "miles/hour", "Deg", "Deg", "miles/hour", "miles/hour", "Degrees", "W/m²", "inch", "In
of Hg", "%", "Deg F", "Deg F"
"", "", "", "Min", "Avg", "Avg", "Smp", "WVc", "WVc", "WVc", "Min", "Max", "SMM", "Avg", "Tot", "Avg", "Avg", "Avg", "Avg"
"ULONG", "ULONG", "ULONG", "FP2", "FP2", "FP2", "FP2", "FP2", "FP2", "FP2", "FP2", "FP2", "FP2", "FP2", "FP2", "FP2", "FP2", "FP2", "FP2"
€<" EÔ‚H` ` ` ` ` àa`` JJŸþŸþKy
CSV example:
101, 2008, 74, 1600, 0, 13.07, 73.8, 72.98, 20.72, 0, 0, 0, 0, 0, -0.097, 0.021, 0, 26.34, 7999, 7999, 29.37
Nota: lo siguiente muestra información de compatibilidad notable. No es una lista de todos los productos compatibles.
Producto | Compatible | Nota |
---|---|---|
CR1000 (retired) | ||
CR200X (retired) | ||
CR216X (retired) | ||
CR3000 (retired) | ||
CR5000 (retired) | ||
CR800 (retired) | ||
CR850 (retired) | ||
CR9000X (retired) |
Producto | Compatible | Nota |
---|---|---|
21X (retired) | ||
CR10 (retired) | ||
CR10X (retired) | ||
CR23X (retired) | ||
CR500 (retired) | ||
CR510 (retired) | ||
CR9000 (retired) |
Upgrade Baler version 2.2 or 3.4 to 4.0; no intermediate steps are required.