4WHB10K 10 kohm, 4-Wire Half-Bridge Terminal Input Module

Resumen

The 4WHB10K provides the completion resistor required for four-wire half-bridge measurements. This module should be used with sensors that have a 10 kΩ resistance.

Leer más

Ventajas y características

  • Realiza una medida precisa de un puente medio a 4 hilos de 10kohm
  • Fácil de instalar o quitar
  • Se conecta directamente en los terminales de entrada del datalogger
  • Compatible con la mayoría de dataloggers Campbell Scientific

Imágenes

Descripción detallada

4WHB10K Schematic 

4WHB10K-to-Sensor Hookup


Preguntas frecuentes

Número de FAQs relacionadas con 4WHB10K: 2

  1. The 4WPB100, 4WPB1K, and 4WHB10K terminal input modules can be used instead of the 3WHB10K module. However, ensure that the jumper is installed between the ground side of the sensor and the low input of the second channel to maintain the four-wire accuracy.


Especificaciones

Used With 4-wire half bridge measurements with a 10 kΩ resistance
Resistance 10 kΩ (bulk metal foil)
Tolerance ±0.01% (@ 25°C)
Maximum Temperature Coefficient ±0.8 ppm/°C
Power Rating 0.25 W (@ 70°C)
Dimensions 1.5 x 1.5 x 2.7 cm (0.6 x 0.6 x 1.0 in.) for body with prongs
Weight 6 g (0.2 oz)

Compatibilidad

Nota: lo siguiente muestra información de compatibilidad notable. No es una lista de todos los productos compatibles.

Dataloggers

Producto Compatible Nota
CR1000 (retired)
CR200X (retired)
CR216X (retired)
CR300 (retired)
CR3000 (retired)
CR310
CR350
CR5000 (retired)
CR6
CR800 (retired)
CR850 (retired)

Miscelaneo

Producto Compatible Nota
21X (retired)
CR10 (retired)
CR10X (retired)
CR23X (retired)
CR500 (retired)
CR510 (retired)
CR9050 (retired)

Información de compatibilidad adicional

Data Logger Considerations

The 4WHB10K uses two sequential differential analog inputs; the first differential channel must have an adjacent analog ground channel to accept the "ground prong" of the 4WHB10K. Not all data logger terminal strips have this sequence on all channels, so please check your data logger's wiring panel to confirm channel assignments, especially if you plan to use multiple Terminal Input Modules.

Newer CR10X Wiring Panels and the CR10XTCR Thermocouple Cover are deep enough to cover the data logger input channels with a Terminal Input Module attached; older CR10TCRs are not deep enough.

Programming

The 4WHB10K is measured either with CRBasic's BrHalf4W Instruction or Edlog's Instruction 9 (Full-Bridge with Excitation Compensation).