This glossary lists the words that commonly appear in Campbell Scientific documents and defines those words as we apply them. The definitions are intentionally brief. In-depth and technical discussions are provided in our manuals.
-6999: This number is associated with mixed-array dataloggers. It is the minimum value that can be stored as a low resolution data point in a mixed-array datalogger. This number will be stored in the input location assigned to a measurement if the voltage input exceeds the programmed range.
-99999: This number is associated with mixed-array dataloggers. It is the minimum value that can be stored as a high resolution data point in a mixed-array datalogger. This number will be stored in the input location assigned to a measurement if the voltage input exceeds the programmed range.
A/D Bits: The number of bits used to convert an analog signal to a digital value.
AE (Application Engineer): A Campbell Scientific employee whose job is to help customers configure data acquisition systems that fit their applications, provide quotes, assist ordering, answer technical questions about our equipment, and occasionally help program or install equipment. AEs who primarily focus on sales activities and system configuration are titled Sales Engineers. AEs who focus on technical support and troubleshooting are titled Customer Support Engineers.
ALERT (Automated Local Evaluation in Real Time): A data transmission protocol used in flood warning systems.
Aliasing: The erroneous interpretation of high-frequency signals as lower-frequency signals. Such misinterpretations are expected result of making discrete measurement with sampling devices such as analog-to-digital (A/D) converters. See also anti-aliasing filters.
Analog Ground: Terminals on the datalogger that provide a ground reference for a single-ended measurements or for excitation return.
Analog Inputs: Channels for measuring voltage levels. Each channel is programmed with software selectable voltage ranges allowing the best measurement range to be specified for a given sensor's output signal. Analog inputs can be configured to make single-ended or differential measurements. See single-ended and differential measurements.
Analog Inputs: Channels for measuring voltage levels. Each channel is programmed with software selectable voltage ranges allowing the best measurement range to be specified for a given sensor's output signal. Analog inputs can be configured to make single-ended or differential measurements. See single-ended and differential measurements.
Analog Voltage Resolution: The smallest change in an input voltage that our dataloggers can detect.
Anemometer: A sensor that measures wind speed. Cup, propeller, and sonic anemometers are available.
Anti-Aliasing Filter: A device that attenuates signal content outside the desired bandwidth. It precedes the analog-to-digital converter (ADC) in instrumentation designs theoretically allowing only frequencies in the pass-band to be sampled by the ADC. See also aliasing.
Aquaculture: The cultivation of fish or shellfish, i.e., fish farms. Campbell Scientific dataloggers are compatible with equipment for monitoring water quality (especially dissolved oxygen) and other conditions that could affect the health of fish.
Argos System: A satellite telemetry system that uses two satellites with polar orbits. Full global coverage including the poles is provided. Transmissions are limited to 16 low resolution data points. To use the Argos system, you must pay a fee and the data that will be transmitted must be used for meteorological purposes.
ASCII (American Standard Code for Information Interchange): Pronounced "askee"; a specific binary code of 128 characters represented by a string of seven binary numbers and a parity bit.
ASCII, Comma Separated: A file format option available in Campbell Scientific dataloggers that strips all IDs, leading and trailing zeroes, unnecessary decimal points, and plus signs. Data points are separated by commas; arrays are separated by Carriage Return Line Feeds. This format is typically the easiest to import to data reduction or spreadsheet software such as Excel, DaDisp, Access, or our SPLIT program.
ASCII Printable: A file format option available in Campbell Scientific data loggers that precedes each data point with a 2-digit ID and a + or - sign. The ID and fixed spacing of the data points make specific data easy to locate on a printed output. This format is difficult to import to data reduction or spreadsheet software. SPLIT can be used to convert this format to ASCII, Comma Separated.
Aspirated: To drain air through by suction. This usually refers to the radiation shields used with air temperature sensors. Naturally aspirated shields rely on ambient wind to keep air moving past the sensor. Mechanically aspirated shields draw air past the sensor using fans.
Asynchronous: The transmission of data between a transmitting and a receiving device that occurs as a series of zeros and ones. For the data to be "read" correctly, the receiving device must begin reading at the proper point in the series. In asynchronous communication, this coordination is accomplished by having each character surrounded by one or more start and stop bits which designate the beginning and ending points of the information (see Synchronous).
AWG: A standardized system for sizing wires based on the wire's diameter. The smaller the AWG number the larger the diameter of wire.
AWS (Automated Weather Station): A weather station that accurately and automatically measures and records meteorological variables over extended periods.
Barometer: A sensor that measures barometric pressure.
Barometric Pressure: The pressure of the atmosphere expressed in units of mbars, psig, or Hg (inches of mercury).
Base Station: A focal point for data and communications. One base station can service one or more remote sites.
Battery-backed: A system or component with an auxiliary battery that allows information in volatile storage areas to be retained if the main power supply has been cut off.
Baud Rate: The speed of information being transmitted across a serial interface, expressed in units of bits per second (bps). For example, a baud rate of 9600 refers to bits being transmitted (or received) from one piece of equipment to another at a rate of 9600 bps. Thus, a seven bit ASCII character plus parity bit plus one stop bit (total nine bits) would be transmitted in 9/9600 sec. = 0.94 ms or about 1000 characters/sec. When communicating via a serial interface, the baud rate settings for two pieces of equipment must match.
Beacon: A signal broadcasted to other devices in a PakBus® network to identify the neighbor devices. A beacon in a PakBus network ensures that all devices in the network are aware of the other devices that are viable. If configured to do so, a clock set command may be transmitted with the beacon interval. This function can be used to synchronize the clocks of devices within the PakBus network. See also PakBus and Neighbor Device.
Binary: A file format option using patterns of 0s and 1s to represent each of the characters. This format is the most compact to store on the PC but must be converted before it can be imported, printed, or read. The binary format offers no advantage in data retrieval speeds because data is always transmitted using the binary format. This format option only refers to the format of the file stored on the computer. Programs such as SPLIT can be used to convert binary formats to ASCII, Comma Separated.
Bit: The smallest unit of computer information. Each bit is either a "1" or "0".
Bowen Ration System: A system using air temperature, net radiation, soil heat flux, and dew point measurements to estimate evapotranspiration. The Bowen ratio technique increases accuracy by measuring air temperature at two heights. Campbell Scientific's system uses air samples from two heights that are forced through mixing volumes and routed to a cooled mirror dew point hygrometer.
Bridge Measurements: See full-bridge or half-bridge.
Burst Mode: An instruction available in the CR10(X), CR510, and CR23X that allows the datalogger to measure sensors at a faster speed over short intervals.
Byte: A group of eight bits that a computer processes as a unit.
Callback, call back, or call-back: Telecommunications with a datalogger where communications is initiated by the datalogger, usually in response to a measured condition or set of conditions, generally for the purpose of sounding an alarm at a remote computer. With a voice-synthesizer phone modem a datalogger can call a telephone number and dictate an appropriate message. Callback is also used where it is impractical to call the datalogger but the datalogger can call out.
CANbus, CAN: A protocol developed by automobile manufacturers enabling a vehicle's on-board computer diagnostic system to output standardized data streams. Dataloggers that include the CANbus instruction can store data output from the vehicle's computer, typically along side measurements taken directly by the datalogger.
CCT (Customer in Control TechnologyTM): A new concept for the RWIS industry. CCT permits customers to specify best-of-breed hardware and PC software, including products from other CCT vendors. The customer of a CCT-based system owns the data, which allows the customer to modify and redistribute the data without additional costs. See also RWIS.
Common Mode Range: The voltage range, relative to the datalogger ground, within which both inputs of a differential measurement must lie in order for the differential measurement to be made. Refer to the datalogger manual or Edlog help to determine the common mode range for specific datalogger models. Also see differential measurements.
Completion Resistor: A resistor, typically a precision resistor, that completes a bridge measurement system and across which a voltage drop is measured.
Compression Fitting: Individual cable entry fittings included in some of our enclosures. Each compression fitting accommodates a sensor cable and when the fitting's rotated, clamps tightly against the sensor cable providing a water-tight seal.
Continuous Analog Outputs (CAO): Outputs providing programmable voltage levels (at low amperages) to strip chart recorders or proportional controllers.
Control Ports: Another name for digital I/O ports, although often applies to output only channels found in our older dataloggers. These ports were typically used to control external devices.
CRBasic: A datalogger program editor whose structure stems from the BASIC programming language. CRBasic supports keyword, algebraic expressions, and conditional expressions. Dataloggers that use CRBasic include our CR200(X)-series, CR800, CR850, CR1000, CR3000, CR5000, and CR9000(X).
CRBasic Dataloggers: Dataloggers that use the CRBasic program editor, which includes our CR200(X)-series, CR800, CR1000, CR3000, CR5000, and CR9000(X) dataloggers.
CS I/O Port: A nine-pin "D" style port on Campbell Scientific dataloggers for connecting data transfer and storage peripherals such as phone, RF, or short haul modems. Low state is 0 V; high state is 5 V. If the datalogger does not have a port that's labeled RS-232, then this port is also used to connect the datalogger to the computer's RS-232 port. However, an RS-232 interface such as the SC32A is required.
Current: Flow of electrons through a circuit.
Current Drain: The amount of current used by a device.
Current Shunt: A resistor that converts a current signal to voltage signal.
Data Acquisition: The process of acquiring data.
Data Acquisition System: One or more electronic devices whose primary purpose is to acquire data. It can be simple or complex, depending upon your needs. Typically a data acquisition system involves at least three main components. First, sensors respond to a physical stimulus and transmit signals or change electrical property such as resistance. Second, a datalogger measures the electrical signal, converts it to a number and stores either that value or some statistics on that value (average, maximum, minimum, standard deviation, etc.). Third, a PC uses some communications link (serial port, phone modem, radio modem, etc.) to retrieve the data from the datalogger. The resulting data is only as good as the sensors can measure and the datalogger can resolve. Reliable communications and software on the PC are critical to retrieving an accurate copy of the data in a timely fashion.
Datalogger: Also known as Measurement and Control System or Micrologger. Dataloggers are the brain of a data acquisition system. They make measurements at a specified scan rate, process data, and initiate telecommunications. Our dataloggers also have control capabilities allowing them to automatically respond to a specified conditions by controlling external devices (e.g., opening flood gates, turning fans off/on).
Data Point: A data value which is sent to Final Storage as the result of an output processing (data storage) instruction. Strings of data points output at the same time make up a record in a data table.
Data Retrieval: Retrieving data from a datalogger, RTU, or field recording device. With the appropriate data retrieval peripherals, this can be done either locally or remotely.
DCP (Data Collection Platform): A term used in reference to transmitting data via the GOES satellite system. The data collection platform is the field site where the datalogger makes the measurements and where the satellite transmitter transmits the data to the satellite.
DDE (Dynamic Data Exchange): A protocol for allowing different software applications or programs to share information.
Desiccant: Packets of drying agent used in our enclosures to extract water vapor from the enclosed environment thereby protecting the electronic equipment from condensing humidity.
DevConfig (Device Configuration Utility): A utility for setting up Campbell Scientific hardware. DevConfig allows you to send new operating systems to devices with flash memory, configure various PakBus settings in dataloggers, and edit settings for Campbell Scientific devices such as the MD485, RF400, and SC105. DevConfig is bundled in PC400, LoggerNet, and RTDAQ, and is available at no charge from our website.
Dew Point: The temperature at which water vapor begins to condense.
Differential Measurements: Analog measurements in which the voltage is measured between two inputs. Both inputs must be within the datalogger's common mode range. Differential measurements may eliminate errors due to a difference in ground potential between the datalogger and sensors, such as when external signal conditioning circuitry is powered from the same source as the datalogger. Differential measurements have better noise rejection than single-ended measurements. See common mode range and single-ended measurements.
Digital I/O Ports: Input/output ports that sense status, read SDM peripherals or SDI-12 sensors, and control external devices.
E08: An error code indicating the watch dog timer has reset the processor and program execution. Frequent repetitions of E08 indicate a hardware or software problem which should be reported to Campbell Scientific and diagnosed with the help of an AE.
Earth Ground: 1) Using a grounding rod or another suitable device to tie a system or device to the earth at the datalogger site. Such a connection is used as a sink for electrical transients and possibly damaging potentials, such as those produced by a nearby lightning strike. 2) A reference potential for analog voltage measurements. Note that most objects have a "an electrical potential" and the potential at different places on the earth ? even a few meters away ? may be different. See ground loop.
Eddy Covariance: System that calculates atmospheric and vapor fluxes. Campbell Scientific's systems are based around a sonic anemometer and Krypton hygrometer and possibly a CO2/H2O open path analyzer.
Edlog: A datalogger program editor that was designed for a 16-key keyboard (0-9, A-D, *, and #) and a 7-segment display. No computer is necessary, but computer-generated program files are often used. For many applications, our Short Cut software makes programming these dataloggers extremely easy. Dataloggers that use Edlog programming include our CR510, CR10(X), CR23X, and CR7.
Edlog Dataloggers: The datalogger that are programmed using the Edlog program editor. Dataloggers that use Edlog programming include our CR510, CR10(X), CR23X, and CR7.
EEPROM (Electronically Erasable Programmable Read Only Memory): The memory that stores the datalogger operating system and user programs.
Ethernet: A communication system that connects computers into a high-speed network. Often, the Ethernet is used for Local Area Networks (LANs) because it can network many types of computers and is not proprietary. To communicate in an Ethernet network, most Campbell Scientific dataloggers use an interface (see www.campbellsci.com/internet-ip-networks). Our CR9000X dataloggers have an onboard 10baseT/100baseT Ethernet connector, and therefore an interface is not required.
ETo: Notation for potential evapotranspiration.
Evapotranspiration: The amount of water no longer available in the soil due to evaporation and transpiration. Transpiration is the movement of liquid through a plant then released through the stomata of the plant as water vapor. There are several methods for estimating evapotranspiration including the Penman Monteith equation and Bowen ratio technique.
Excitation: Programmable voltage provided for bridge measurements. See also switched excitation channels, full-bridge, and half-bridge.
Execution Interval: See scan, scan interval, or scan rate.
Execution Time: The time required to execute an instruction or group of instructions. The execution time should be shorter than the execution interval so that the datalogger can complete the instruction set as written every time it's initiated. If the execution time of a Program Table exceeds the table's Execution Interval, the Program Table will be executed less frequently than programmed resulting in table overruns.
External Signal Conditioning: Using peripheral devices to alter a sensor's signal so that an otherwise non-compatible device can read the signal. Signal conditioning circuits can be quite complex (e.g., temperature-compensated voltage output devices) or simple (e.g., a precision resistor used as a voltage divider).
FAO 56 Penman-Monteith or FAO 56 PM Equation: A version of the Penman- Monteith equation that is accepted by the Food and Agriculture Organization of the United Nations (FAO) as a method to estimate evapotranspiration from a turf grass surface, in all regions and climates. Campbell Scientific's Visual Weather software uses this equation. The equation was originally published in "Crop Evapotranspiration, Guidelines for Computing Crop Water Requirements, FAO Irrigation and Drainage Paper 56", Richard G. Allen, Luis S. Pereira, Dirk Raes, and Martin Smith, Food and Agriculture Organization of the United Nations, Rome, 1998. See also evapotranspiration and Penman Monteith equation. Penman Monteith Equation: An equation for estimating evapotranspiration using a turf grass reference. It requires wind speed, air temperature, relative humidity, and solar radiation measurements. See also evapotranspiration.
FFT (Fast Fourier Transform): A mathematical function describing the relative magnitudes and phases of frequencies in a time varying signal.
Fiber Optic: A data retrieval hardware link using a bundle of thin transparent fibers of glass or plastic that transmit light throughout their length by internal reflections.
FIELDbus: A communications protocol sometimes used in SCADA systems.
Fill and Stop Memory: A memory option for external data storage devices. Data will be written to the memory until it is filled. Once full, the device won't allow any more data points to be written until the memory has been erased.
Final Storage: That portion of the datalogger SRAM Memory allocated for storing data tables with output arrays. Final Storage is a ring memory, with new data overwriting the oldest data.
Final Storage Area 1 or Area 2: These terms are used in connection with Edlog programming and our legacy dataloggers. The two independent Final Storage areas provided in the CR10(X), CR510, and CR23X; only one Final Storage area is available in the CR500, 21X, or CR7. Use of Final Storage Area 2 is determined by the datalogger program. Data can be directed to, and collected from, one or both of the areas.
Firmware: Programs or instructions stored in a PROM or EEPROM.
Flash Memory: Non-volatile memory used in our dataloggers and other devices. Flash memory is used for data storage.
Full-bridge: System of four resistors that change resistance based upon some type of physical property (e.g., pressure, temperature). Full bridge circuits are usually more sensitive to change and are useful for sensors that produce a small change in resistance. Also known as Wheatstone bridge.
Full Duplex: Operational mode of a communication circuit in which each end can simultaneously transmit and receive data.
Full Scale Range (FSR): The full measurement range of a measurement channel or sensor.
G: Datalogger terminals directly connected to the Earth Ground or Ground Lug terminal.
Garbage: The refuse of the data communication world. When data are sent or received incorrectly (and there are numerous reasons this happens), a string of invalid, meaningless characters (garbage) results. Two common causes are: 1) a baud rate mismatch and 2) synchronous data being sent to an asynchronous device or vice versa.
Geostationary Satellite Systems: Satellite systems whose satellites have orbits that coincide with the earth's rotation allowing each satellite to remain above a specific region. GOES and Inmarsat are geostationary systems.
Gill Radiation Shield: A naturally aspirated shield that houses temperature probes in order to reduce the effects of solar loading on the temperature measurement.
GOES (Geostationary Operation Environmental Satellites) System: A geostationary satellite system available to only U.S. Federal, State, or local government agencies or users sponsored by one of those agencies. Potential GOES users must receive formal permission from NESDIS (the agency that coordinates GOES). See also Geostationary Satellite Systems.
GPS (Global Positioning System): A satellite system used to determine geographic position and deviation. Campbell Scientific dataloggers can interrogate some GPS receivers then store the GPS position data.
Ground Loop: An alternative path in which voltage can travel. Ground loops can produce measurement errors. Refer to the sensor's manual for tips on avoiding ground loops.
Ground Lug: A lug used for connecting our dataloggers to earth ground. Our dataloggers must be connected to earth ground to protect them from transient potentials such as nearby lightning strikes.
GUI (Graphical User Interface): Pronounced "gooey"; the programming code defining the operation and graphics displayed on a computer monitor. It's the code that drives the "look and feel" of a computer program.
Guy: Cables attached to a tripod or tower to increase stability. Our 30 foot towers must be guyed. Other towers and tripods may be guyed if increased stability is required.
Half Bridge: System of two or more resistors wired in a series that change resistance based upon some change in of physical property (e.g., pressure, temperature). Refer to the measurements chapter in the datalogger manuals.
Half Duplex: Operational mode of a communication circuit in which each end can transmit and receive data, but not simultaneously.
Handshake, Handshaking: The exchange of predetermined information between two devices to assure each that it is connected to the other. When not used as a clock line, the CLK/HS (pin 7) line in the datalogger CS I/O port is primarily used to detect the presence oabsence of peripherals such as a storage module. Phone modems also handshake when they connect (sounds like screeching).
High Resolution Data Value: For mixed-array dataloggers, the data value having five significant digits and ranging in magnitude from ± 0.00001 to 99999. A high resolution data value requires two final storage locations (4 bytes) and must be specified by Instruction 78.
Hygrometer: A sensor that measures dew point.
Indexed Input Location: This is used in Edlog. Commonly used with multiplexers or when repeating a series of identical measurement/processing instructions. Indexing an input location within a loop (Instruction 87) will cause the location address to be incremented by one with each pass through the loop. Indexing is also used with Instruction 75 to cause an input location, which normally remains constant, to be incremented with each repetition. See also indexing parameters.
Indexing Parameters: Altering the function of a parameter by pressing the F4 function key or C key. Not all parameters can be indexed, and the affect of indexing varies according to the parameter. To determine what parameters can be indexed, refer to the datalogger's prompt sheet, individual instruction descriptions in the datalogger manual, or Edlog help for individual instructions. In Edlog, a parameter is indexed by pressing the F4 function key while in the numeric or label field of the parameter, or the C key while in the numeric field of the parameter. If using the keyboard display, press the C key then the A key. Two dashes will be displayed after the entry indicating the parameter has been indexed. Pressing the respective key when a parameter is already indexed will toggle the index off.
Inmarsat System: A commercial Geostationary satellite system. The Inmarsat system maintains a satellite in each of four ocean regions: Atlantic Ocean East, Atlantic Ocean West, Pacific Ocean, and Indian Ocean. These satellites provide coverage throughout most of the world. To use this system, you must pay a fee and your site must be located where an Inmarsat satellite provides coverage. See also Geostationary Satellite Systems.
Input Bias Current: The average input current of two input terminals.
Input Impedance: The shunt resistance and capacitance (or inductance) measured at the input terminals, without including the effects of input bias or offset currents.
Input Locations: Used in Edlog. These are addresses in the datalogger memory where measurement results are temporarily stored. Old data are overwritten by new measurement results with each new execution interval. The values stored in input locations are displayed in the Monitor or Graph Mode. When using the datalogger's keyboard display, the input location values are displayed in the *6 mode. Input location values are not the values retrieved when data are collected.
Input/Output Instructions: Instructions that initiate measurements and store the results in Input Storage, or set or read Control/Logic Ports.
Input Storage: In Edlog, this is the area of the datalogger memory that stores input location data. Default is 28 locations for most dataloggers. The number of allocated locations can be changed using Edlog or the keyboard display's *A mode. See input locations.
Instruction Location Number: In Edlog, this number gives the sequential location of the instruction in the program sequence. When programming a table, the instruction location number and a P (e.g., 04: P00) prompts the user when it is time to enter an instruction.
Interfaces: Devices allowing one piece of equipment to "talk" to another one.
Intermediate Disable Flag (Flag 9): This flag suspends intermediate processing when it is set high. This Flag is used to restrict the sampling of averages, totals, maximums, minimums, etc. to times when certain criteria are met. The Intermediate Disable flag is set as a command code option in a program control instruction. The flag is automatically set low at the beginning of each execution of the program table.
Intermediate Storage: That portion of memory allocated for the storage of results of intermediate calculations necessary for operations such as averages or standard deviations. Intermediate storage is not accessible to the user.
Keyboard Display: A sixteen button keypad and LCD that allows you to manually initiate data transfer and display sensor readings, stored values, or flag/port status. The CR850, CR3000, CR5000, CR7, CR23X, and 21X have integrated keyboard displays. The CR800 and CR1000 use the portable CR1000KD. The CR10(X), CR510, and CR500 use the CR10KD. The CR200(X)-series dataloggers and CR9000X dataloggers do not have a keyboard display.
Line-of-Sight: A straight path between a transmitting and receiving antenna that's unobstructed by intermediate topography. RF telemetry systems require line-of-sight transmissions. The use of repeater stations can overcome line-of-sight interruptions.
Loop: In a program, a series of instructions that are repeated a prescribed number of times, followed by an "end" instruction to terminate the series.
Loop Counter: A counter that increments by one with each pass through a loop.
Low Resolution Data Value: For our mixed-array dataloggers, this is the default output resolution from Final Storage. A low resolution data value requires one Final Storage location (2 bytes) and has four significant decimal digits that may range in magnitude from ±0.001 to ±6999.
LVDT (Linear Variable Differential Transformer): An inductance element that produces an electrical output proportional to the displacement of a separate movable core; used to measure position.
mA (milliampere): Unit of current that's one thousandth of an ampere.
Manually Initiated: Initiated by the user, usually with a keyboard, as opposed to occurring under program control.
Maximum Input Voltage: The largest input voltage value that the datalogger can read. An input voltage greater than this value will cause errors and possible overranging on the other analog inputs. Voltages significantly larger than the maximum input voltage may permanently damage the datalogger.
Mean Time Between Failures (MTBF): A quality assurance index describing the expected reliabitilty of our dataloggers.
Measurement and Control Systems: A more descriptive name for Campbell Scientific dataloggers. Historically, dataloggers were relatively "dumb devices" that had limited programming and no control capabilities. Campbell Scientific uses the name measurement and control system to inform the users that our dataloggers have measurement and control capabilities and are not the "dumb devices" historically associated with the name datalogger.
Measurement Current Drain: The amount of current our dataloggers use to make measurements.
Meteor Burst: A telecommunication technique which uses meteor activity in the ionosphere as a mechanism for reflecting short data transmissions from field sites to a base station. Transmissions are "bounced" from a ground station, reflected off the ionosphere and received at another ground station.
Meteorological: Of or pertaining to atmospheric phenomena, especially weather and weather conditions.
Micrologger: The trademarked name for our CR3000, CR23X, 21X and CR21 dataloggers. Our Microloggers traditionally are compact, self-contained (i.e., keyboard display, power supply are part of unit), and have a set number of I/O terminals (not card or module based like the CR9000X).
Micrometeorology: The detailed study of the weather at a specific location.
Mixed Array Memory Structure: A memory structure used by many of our retired dataloggers. This type of memory stores arrays of data at specified intervals or when some other set condition has been met. As data is stored, each array of new data is added sequentially to a common storage area (Final Storage). After the data has been collected, it can be separated into files based on various criteria by using Split (part of LoggerNet and PC208W) or some other software program. The mixed array memory structure is used by our CR10, 21X, and CR7 dataloggers. Our CR510, CR10X, and CR23X dataloggers may also use this memory structure (the memory structure of these dataloggers is determined by the selected operating system). Terms associated with mixed array memory structure include Final Storage, Output Array, Output Array ID, Output Flag, and Output Interval.
Modbus: Communication protocol developed by Modicon; widely used in SCADA and process control applications. Many of our dataloggers support the Modbus protocol.
Modem: A device whose name combines the term "modulate" with "demodulate" which refers to its ability to transmit and receive data superimposed on a carrier frequency. In our usage, a modem also: 1) has the ability to raise the datalogger's ring line or be used with the SC32A to raise the ring line and put the datalogger in the Telecommunications Command State and 2) has an asynchronous serial communication port that can be configured to communicate with the datalogger.
MSHA (Mining Safety and Health Administration): Pronounced "em shaw"; an organization that sets safety requirements for mines. Historically, Campbell Scientific manufactured MSHA-approved equipment for use in methane environments, but a lack of available approved parts has resulted in the discontinuation of this line.
Multidrop Modem or Interface: Devices linking one computer to many dataloggers on a common cable or wire. Multidrop modems have addresses which allow one datalogger to communicate with the computer while the other dataloggers remain in a quiescent state.
Multiplexer: Peripherals that increase the number of sensors that can be measured by the datalogger. Multiplexers essentially allow multiple sensors to share the same datalogger channel. Several multiplexers can be controlled by a single datalogger. The CR510, CR500, and CR200-series dataloggers do not support multiplexers.
Mux: Slang for multiplexer.
mV (millivolt): A unit of electrical potential equal to one thousandth of a volt. This is a typical output for sensors. In many sensors, the mV signal level varies to indicate change is occurring in the parameter measured.
Narrowband UHF/VHF: A type of RF telemetry that transmits data over a UHF or VHF frequency. An assigned frequency and an FCC license are required. See also RF telemetry, UHF, VHF, and Spread Spectrum.
Neighbor Device: Devices in a PakBus® network that can communicate directly with an individual device without being routed through an intermediate device. See also PakBus and Beacon Interval.
Net Radiometer: A sensor that measures net flux of downward and upward total solar and terrestrial radiation through a horizontal surface.
NIST (National Institute of Standards and Technology): An organization in the United States that sets measurement standards. The organization was once called NBS (National Bureau of Standards).
Node: Part of the description of a datalogger network when using LoggerNet. Each node represents a device that the communications server will dial through or communicate with individually. Nodes are organized as a hierarchy with all nodes accessed by the same device (parent node) entered as child nodes. A node can be both a parent and a child.
Noise: Undesirable electrical energy that interferes with accurate measurements.
Omnidirectional Antenna: An antenna that can pick up signals from all directions (i.e., it doesn't have to be pointed directly at the source of the signal to pick it up). Typically this type of antenna is used when the specific direction of the signal is not known, when one antenna is receiving and transmitting in several directions (as in a repeater station in an RF network), or for mobile applications.
On-Site Data Transfer: Routine transfer of data to a peripheral that remains on-site. Transfer is controlled by the program entered in the datalogger.
Optional Data Memory: Extra data memory that is available if an additional memory option for the datalogger has been ordered.
OS (Operating System): The portion of the memory of a datalogger or other device containing the instruction set. The OS of these devices can be changed without opening the device and changing a hardware PROM. The new operating system can be downloaded from a computer connected directly to the device.
Output Array: A string of data points output to Final Storage. Output occurs when the data interval and data trigger are true. The data points which complete the Array are the result of the Output Processing Instructions which are executed while the Output Flag is set.
Output Array ID: The first data points of an Output Array when using Edlog. By default, the Output Array ID consists of the Program Table Number and the Instruction Location Number of the program instruction that set the Output Flag. For example, if the 40th instruction in the datalogger's Program Table 2 is an Instruction 92 that designated data to be output at three hour intervals, the default Output Array ID for that output data will be 0240. The output array ID can also be specified using Instruction 80 in the datalogger program.
Output Flag (Flag 0): A flag telling the datalogger to send data to Final Storage. The output flag is set by entering option 10 for the command code parameter in a program control instruction. Data must be in Final Storage to transfer it to a storage module or printer, or to retrieve the data via a telecommunication link.
Output Interval: The time interval between initiations of a particular Output Array. Output occurs only when the Output Flag is set. The flag may be set at fixed intervals or in response to certain conditions.
Output Processing Instructions: Process data values and generate Output Arrays. Examples of Output Processing Instructions include Totalize, Maximize, Minimize, Average, etc. The data sources for these Instructions are values in Input Storage. The results of intermediate calculations are stored in Intermediate Storage. The ultimate destination of data generated by Output Processing Instructions is usually Final Storage but may be Input Storage for further processing. The transfer of processed summaries to Final Storage takes place when the Output Flag has been set by a Program Control Instruction.
Overrange: A voltage input exceeding the programmed range. When this occurs, the value stored in the variable is NAN (not a number). For our retired dataloggers that use Edlog, the value stored in the input location is -6999 and -99999 for low and high resolution, respectively. Any output processing for that interval will also store an overrange value, even if only one overrange event occurred.
PakBus: A packet-based communications protocol developed by Campbell Scientific. The PakBus communication protocol improves upon traditional communications for datalogger networks. PakBus networks have the distributed routing intelligence to continually evaluate links. Continually evaluating links optimizes delivery times and, in the case of delivery failure, allows automatic switch over to a configured backup route. The PakBus communications protocol is standard in our CR200(X)-series, CR800, CR1000, and CR3000 dataloggers; it's optional in our CR510, CR10X, and CR23X dataloggers.
PakBus Node: A device in the PakBus network that has a unique PakBus ID. The device can be a datalogger, computer, or Ethernet Interface.
Parameter: Number or code entered to specify exactly what a given instruction is to do. Parameters are an integral part of the datalogger's program instructions. Common parameter entries include reps, measurement channels, measurement ranges, input locations, etc. Once the instruction number has been entered in a Program Table, the datalogger will prompt for the parameters by displaying the parameter number in the ID Field of the display.
PDA (Personal Digital Assistant): A hand-held computing device. Some communications are supported between a PDA and our dataloggers; PConnect software is required for PDAs with a Palm OS and PConnectCE software is required for PDAs with a Windows Pocket PC/Windows Mobile OS. For more information, see the PConnect or PConnectCE product literature.
Penman Monteith Equation: An equation for estimating evapotranspiration using a turf grass reference. The equation is sanctioned by the Food and Agricultural Organization of the United Nations. It requires wind speed, air temperature, relative humidity, and solar radiation measurements. Campbell Scientific's ET106 station uses the Penman-Monteith equation. See also evapotranspiration.
PE (Pin Enable): The line on which print devices or peripherals receive output.
Peripheral: Auxiliary or supplementary equipment. Typical Campbell Scientific peripheral equipment includes power supplies, measurement and control electronics (e.g., SDMs, multiplexers), and data retrieval hardware.
Potential Evapotranspiration (ETo): The amount of water that evapotranspiration would remove from a specific site if an ample supply of water was available. See evapotranspiration.
Potentiometer: A variable resistor with three terminals—one on each end of the resistor and one "wiper" which contacts the resistor midpoint to indicate a variable position. Often used in wind vanes.
Power Supplies: An energy source for an electrical device. These can be ac powered through a standard wall socket, or dc powered through batteries and a solar panel. Many data acquisition systems work from a 12 to 24 Vdc power supply that can be kept fully charged by a solar panel or ac power.
Probe: A device used to send back information. Campbell Scientific uses the words probe, sensor, and transducer interchangeably.
Programmable Excitation Ports: Another name for Switched Excitation Channels.
Program Memory: The amount of datalogger memory available for storing user-created programs.
Program Table: That portion of datalogger memory allocated for storing user-created programs. The programs consist of a sequence of user-selected instructions which control data acquisition, processing, and output to Final Storage. Programming can be separated into two tables, each having its own user-defined execution interval. A third table is available for programming subroutines, which may be called by instructions in Tables 1 or 2, or triggered by a voltage on a control port. When using the keyboard display, the *1 and *2 Modes access Tables 1 and 2, respectively, and the *3 Mode accesses Subroutine Table 3. The length of the tables is constrained only by the total memory available for programming. Tables 1 and 2 have independent execution intervals. Table 1's execution has the higher priority; it may interrupt Table 2.
PROM (Programmable Read Only Memory): The portion of the CR10, 21X, or CR7's memory containing the datalogger instruction set. To change the instruction set, the datalogger is opened; the old PROM removed, then a new PROM inserted. PROMs are also used in other devices such as MD9 and RF modems.
Prompt Sheet: A short document that was provided with our retired dataloggers. It contained an abbreviated description of the datalogger instructions and parameters. One prompt sheet was supplied with the manual. It is primarily intended for use in the field by users who are familiar with datalogger programming. Detailed descriptions of instructions and parameters are provided in the manual and Edlog help.
Protocol: Rules determining the format and transmission of data (computer science).
PRT (Platinum Resistance Thermometer): A sensor that uses a bridge measurement (a three- or four-wire half-bridge or a four-wire full-bridge) to measure temperatures. Just like any other resistive materials, platinum has a variable resistance depending on the temperature of the surrounding area and on the length of the platinum. The resistive variability measurement is expressed as "Temperature Coefficient of Resistivity". Platinum's low "temperature coefficient of resistivity" value means that its resistance variability does not swing as widely as many other metals, hence its use. Platinum's variability of resistance due to temperature is reproducible (most metals have this reproducibility), so the thermometer uses resistive measurements. A fifth order polynomial is used to increase the accuracy of the correlation between the temperature change and the corresponding resistance change on platinum because the variability of resistance is reproducible but it is not linear with temperature change.
psi (pounds per square inch): A common unit for expressing pressure measurements.
Pulse Measurements: Measurement type that counts switch closures, low level ac, or high frequency square wave signals. Sensors that use pulse measurements include tipping bucket rain gages, anemometers, and flow meters.
Pyranometers: A sensor that measures solar radiation.
Quiescent: Not in active mode, "asleep". Typically this word is used in our specifications in conjunction with current drain in order for the customer to develop a power budget.
Rain Bucket: Device for measuring rainfall. Tipping bucket rain gages are the most typical sensor offered by Campbell Scientific in this category.
RAM (Random Access Memory): The portion of datalogger memory used for data and running the datalogger program. In newer datalogger models, RAM is battery-backed so that datalogger programs are maintained if the system loses power.
Real-time Monitoring: Observing measured results as they are happening.
Reduced Set ETo Station: An ETo station that uses a modified Penman-Monteith equation to calculate ETo from only solar radiation and air temperature measurements. Saturation vapor pressure is calculated from the previous day's minimum temperature, and an average wind speed value is used. Measuring only solar radiation and air temperature reduces cost, eases installation, and minimizes maintenance. A reduced set ETo station should only be used in sites surrounded by well-watered, vegetated surfaces. Currently Campbell Scientific manufactures one reduced set ETo station, the ET101.
Repeater Station: A station used to increase line-of-sight coverage area or transmission quality for an RF Telemetry system. A measurement station can be used as a repeater, or a central location that does not make measurements can be set up.
REP (Repetition): A parameter used in many input/output and output processing instructions that allows one programming instruction to measure several identical sensors or to process data from several input locations. The sensors must be wired in consecutive channels. When REPs are greater than 1, the input locations are assigned consecutive numbers (e.g., with REPs of 2 and the first input location number is 5, the assigned input location numbers are 5 and 6). The input location's label for each repetition is the original label with an underscore and the next consecutive number appended to the end.
Resistive Tape: A linear sensor in which the electrical resistance changes as water level rises and falls.
RF (Radio Frequency) Telemetry: A telemetry system that transmits data over a radio frequency. Our RF systems are compatible with UHF and VHF frequencies. In the US, an FCC (Federal Communication Commission) license is required to use an RF system.
RH (Relative Humidity): Ratio of the amount of water vapor in the air to the maximum amount of water vapor that could be held at the current temperature.
Ring Line (pin 3): Line pulled high by an external device to "awaken" the datalogger.
Ring Memory: A memory configuration in which data writes to the memory and when the entire memory has been filled, the new data writes over the oldest data.
RMA (Returned Material Authorization) Number: A number indicating that the user has contacted an Application Engineer, and the Application Engineer has confirmed that the product needs repair or recalibration. Before a product will be accepted for repairs or recalibration, the user must contact Campbell Scientific and acquire an RMA number.
ROM (Read Only Memory): The portion of memory that cannot be altered and is used for storing permanent information.
RS-232 Port: A nine-pin DCE port on most of our dataloggers (CR800, CR1000, CR3000, CR5000) used to connect the datalogger to the computer's RS-232 port. If the datalogger doesn't include a port with this label, an RS-232 interface such as an SC32B is required to connect the datalogger to the computer's RS-232 port.
RS-232 (Recommended Standard 232): A loose standard defining how two computing devices can communicate with each other. The implementation of RS-232 in CSI dataloggers to PC communications is quite rigid, but transparent to most users. Implementation of RS-232 in datalogger-to-RS-232 smart sensor communications is quite flexible.
RTD (Resistance Temperature Device): A sensor that measures temperatures with a bridge measurement (a three- or four-wire half-bridge or a four-wire full-bridge). The sensor uses materials that have a variable resistance depending on the temperature of the surrounding area and on the length of the material.
RTU (Remote Terminal Unit): Device used to control/monitor/record sensor results especially in SCADA applications (i.e., our dataloggers can easily serve as RTUs).
RWIS (Road Weather Information System): Weather stations located along the highway that provide local pavement and meteorological data that may affect driving conditions. Individual weather stations in this system are typically called ESS. See ESS for more information.
Sample Rate: The rate at which measurements are made. The measurement sample rate is primarily of interest when considering the effect of time skew (i.e., how close in time are a series of measurements). The fastest sample rates are when measurements are made that are initiated by a single instruction with multiple repetitions.
SCADA (Supervisory Control and Data Acquisition): Systems that integrate measurements control and redundant data storage. For example, water treatment plants often run SCADA systems.
Scan, Scan Interval, or Scan Rate: Interval between executions of a datalogger program. Dependent on datalogger model, scan may be entered as milliseconds, seconds, minutes, hours, or days. A datalogger program is a timed infinite loop, each loop scheduled to begin at the top of each scan interval. Interchangeable with "execution interval".
SDI-12 (Serial Data Interface at 1200 baud): Communication protocol for transferring data between battery-powered data recorders and sensors. Sensors can measure one or more parameters, then transmit the data back to the data logger following the SDI-12 protocol. Both the sensor and the datalogger must follow the protocol specifications. To read more about SDI-12, or obtain a copy of the specification, visit the SDI-12 Support Group Web Site.
SDK (Software Development Kit): Tools that allow software developers to add custom capabilities or interfaces to our datalogger support software. SDKs currently available from Campbell Scientific include BMP5, LoggerNet-SDK, and LoggerNet Server-SDK. See our product literature for more information about the individual products.
Sealed Rechargeable Battery: A battery that can be recharged using solar panels, ac power, or vehicle power.
Seimens (S): Unit of conductivity where 1 S = 1/ohm. SI based unit is S/m.
Sensor: A device that responds to a physical stimulus and transmits a signal or changes electrical property such as resistance. Campbell Scientific uses the words probe, sensor, and transducer interchangeably.
Serial Server: A device that allows serial communication over a TCP/IP communications link.
Shaft Encoder: A device typically used to measure water level. This sensor is based upon the clockwise/counterclockwise rotation of a pulley. As water level rises and falls, a float sitting on the water surface moves with the water. A wire or metal tape connects the float around a pulley and is held taut by a counterweight on the other end.
Short Haul Modems: Asynchronous devices using two unconditioned twisted cables for communications between a datalogger and computer.
Signature: A number which is a function of the data and the sequence of data in memory. It is derived using an algorithm which assures a 99.998% probability that if either the data or its sequence changes, the signature changes. It's primarily used to verify that a datalogger's program has not changed or during the transmission of data via telecommunications. Data "packets" in which the datalogger and computer signatures do not match are retransmitted.
Single-ended Measurements: Analog measurements in which the input's voltage is measured with respect to ground. Twice as many channels are available for single-ended measurements than for differential measurements. See also differential measurements.
Soil Bulk Electrical Conductivity: Conductivity of electricity through soil.
Soil Heat Flux: The amount of heat flowing into a cross-sectional area of soil per unit time.
Soil Volumetric Water Content: The proportion of a volume of soil that is water.
Soil Water Potential: The energy status of water in soil.
Solar Radiation: Radiation originating from the sun.
Split: A report creation and data processing software tool provided in our dataloggger support software.
Spread Spectrum: A sequential signal structure that spreads the normally narrowband information signal over a relatively wide band of frequencies. Spread spectrum radios correlate the signals to retrieve the original signal. Spread spectrum radios are more immune to noise and interference.
SRAM (Static Random Access Memory): The memory that stores the Final Storage data and runs the datalogger program.
Stilling Well: A cylinder installed near a body of water is used to hold and protect hydrological sensors. The stilling well allows water to move in and out freely but dampens wave and current action so as to provide a reasonable representation of the level of the water body.
Storage Module: A device used to transport datalogger data and programs between a field site and an office. It also increases the datalogger's storage capacity by storing data and programs in a solid state module or a memory card.
Storage Module Software (SMS): A legacy program for programming and retrieving data from storage modules. In PC208W, SMS is accessed by clicking Stg Module on the tool bar.
Strain Gage Pressure Transducer: A device measuring changes in electrical resistance in response to pressure changes on a diaphragm with an embedded or engraved strain gage.
Surface Mount Technology: The technology used when components are mounted to the surface of circuit boards. Surface mount technology allows smaller component size, improves signal speed, increases reliability and automation in manufacturing, and requires less handling of parts.
Surge Protector: A device for protecting electronic equipment from damaging voltage levels sometimes occurring in electrical transients.
Switched 12 Volt: An output on the datalogger used to power sensors or devices requiring unregulated 12 volts. This can be done under program control to save power.
Switched Excitation Channels: Channels that provide precision excitation voltages for resistive bridge measurements. Excitation is programmable. The range that the excitation is programmable varies with datalogger model.
Synchronous: The transmission of data between a transmitting and receiving device occurs as a series of zeros and ones. For the data to be "read" correctly, the receiving device must begin reading at the proper point in the series. In synchronous communication, this coordination is accomplished by synchronizing the transmitting and receiving devices to a common clock signal (see Asynchronous).
Synchronous Device for Measurement (SDM): Addressable peripherals that expand digital control ports, analog output ports, or datalogger measurement capabilities. Up to 16 SDMs may be connected to three control ports on the datalogger. The CR510, CR500, and CR200(X)-series dataloggers do not support SDMs.
Table-based Datalogger Memory: A datalogger memory structure in which multiple storage areas (tables) are configured within your datalogger. Each table can be individually sized and collected. This allows like data to be grouped and stored in separate tables. This memory structure is used by our CR200(X)-series, CR800, CR1000, CR3000, CR5000 and CR9000X dataloggers. Our CR510, CR10X, and CR23X dataloggers may also use this memory structure (the memory structure of these dataloggers is determined by the selected operating system).
Table Overruns: Skipped scans occurring when the actual datalogger program run-time is longer than the execution interval. Table overruns may affect the number of samples included in processed analog measurements and can cause errors in pulse measurements.
Task: An entry in our datalogger support software on the Device Map representing a program scheduled for execution or a subsequent datalogger to be called for data retrieval. Scheduling of execution can be done on a regular interval or following a call to a datalogger.
TCP/IP (Transmission Control Protocol/Internet Protocol): A communications protocol commonly used over Ethernet networks or the Internet.
TDR (Time Domain Reflectometry): A system that uses a reflectometer to generate an electromagnetic pulse that is applied to a coaxial system. The resulting reflection waveform is analyzed and stored. The elapsed travel time and pulse reflection amplitude contain information that can be used to determine soil volumetric water content, soil bulk electrical conductivity, rock mass deformation, or other time-domain measurements.