CS210 Enclosure Humidity Sensor
Remote Monitor
Ensure ideal conditions in enclosures
meteorología aplicaciones agua aplicaciones energía aplicaciones flujo gas y turbulencia aplicaciones infraestructuras aplicaciones suelo aplicaciones

Resumen

The CS210 enclosure humidity sensor measures relative humidity levels inside environmental enclosures. The sensor is housed inside the enclosure. A Campbell Scientific datalogger measures this sensor and stores its data.

Leer más

Ventajas y características

  • Permite monitorizar la HR del armario de forma remota
  • Used to schedule desiccant replacement

Imágenes

Descripción detallada

When CS210's measurements indicates that the RH level inside the enclosure is 40% or more, the desiccant should be replaced with another packet. 

By having the datalogger measure the sensor, the measured values can be incorporated into the transmitted data stream of remotely located dataloggers. The probe has an 11-in. (28 cm) cable length, which should be adequate to place the probe near the enclosure conduits.

Preguntas frecuentes

Número de FAQs relacionadas con CS210: 3

Expandir todoDesplegar todo

  1. Campbell Scientific recommends replacing the CS210 after every three to five years of continuous use. Alternatively, if the CS210 probe fails, replace the sensor at that time.

  2. The CS210 does not have any user-serviceable parts, and it does not require any routine maintenance.

  3. The desiccant should be replaced when the top colored dot on the humidity indicator card (pn 28878) turns pink; the humidity indicator card is included in the enclosure supply kit that is shipped with each enclosure. If the CS210, Enclosure Humidity Sensor, is used, replace the desiccant when the measured humidity exceeds 35%.


Especificaciones

Sensor Elan HM2000 series precision bulk-polymer
Relative Humidity Measurement Range 0 to 100% (non-condensing)
RH Output Signal Range 0 to 1.0 Vdc
Precisión ±3% RH (10 to 90% RH) (at 25°C)
Typical Long-Term Stability Better than 3% RH per year
Tiempo de respuesta 10 seconds for a 30% to 90% RH step change (at 25°C, 90% response)
Consumo < 0.5 mA
Voltaje alimentación 5 ± 0.25 Vdc
Tiempo asentamiento 10 s
Rango temperatura funcionamiento 0° to 50°C
Longitud de cable 27.9 cm (11 in.)
Sensor Head Dimensions 2.5 x 1.3 x 0.8 cm (1.0 x 0.5 x 0.3 in.)
Peso 9 g (0.3 oz)

Compatibilidad

Nota: lo siguiente muestra información de compatibilidad notable. No es una lista de todos los productos compatibles.

Dataloggers

Producto Compatible Nota
CR1000 (retired)
CR200X (retired)
CR216X (retired)
CR300 (retired)
CR3000 (retired)
CR310
CR350
CR5000 (retired)
CR6
CR800 (retired)
CR850 (retired)
CR9000X (retired)

Miscelaneo

Producto Compatible Nota
21X (retired)
CR10 (retired)
CR10X (retired)
CR23X (retired)
CR500 (retired)
CR510 (retired)
CR9000 (retired)