The CS210 enclosure humidity sensor measures relative humidity levels inside environmental enclosures. The sensor is housed inside the enclosure. A Campbell Scientific datalogger measures this sensor and stores its data.
Leer másWhen CS210's measurements indicates that the RH level inside the enclosure is 40% or more, the desiccant should be replaced with another packet.
By having the datalogger measure the sensor, the measured values can be incorporated into the transmitted data stream of remotely located dataloggers. The probe has an 11-in. (28 cm) cable length, which should be adequate to place the probe near the enclosure conduits.
Número de FAQs relacionadas con CS210: 3
Nota: lo siguiente muestra información de compatibilidad notable. No es una lista de todos los productos compatibles.
Producto | Compatible | Nota |
---|---|---|
21X (retired) | ||
CR10 (retired) | ||
CR1000 (retired) | ||
CR10X (retired) | ||
CR200X (retired) | ||
CR216X (retired) | ||
CR23X (retired) | ||
CR300 (retired) | ||
CR3000 (retired) | ||
CR310 | ||
CR350 | ||
CR500 (retired) | ||
CR5000 (retired) | ||
CR510 (retired) | ||
CR6 | ||
CR800 (retired) | ||
CR850 (retired) | ||
CR9000 (retired) | ||
CR9000X (retired) |
Sensor | Elan HM2000 series precision bulk-polymer |
Relative Humidity Measurement Range | 0 to 100% (non-condensing) |
RH Output Signal Range | 0 to 1.0 Vdc |
Precisión | ±3% RH (10 to 90% RH) (at 25°C) |
Typical Long-Term Stability | Better than 3% RH per year |
Tiempo de respuesta | 10 seconds for a 30% to 90% RH step change (at 25°C, 90% response) |
Consumo | < 0.5 mA |
Voltaje alimentación | 5 ± 0.25 Vdc |
Tiempo asentamiento | 10 s |
Rango temperatura funcionamiento | 0° to 50°C |
Longitud de cable | 27.9 cm (11 in.) |
Sensor Head Dimensions | 2.5 x 1.3 x 0.8 cm (1.0 x 0.5 x 0.3 in.) |
Peso | 9 g (0.3 oz) |