RETIRED ›
This product is not available for new orders. We recommend ordering: CR1000.
CR10X-2M Measurement & Control Datalogger with 2 M Additional Memory and Wiring Panel
Services Available

Resumen

The CR10X-2M stored up to 1,000,000 data points.

The CR10X-2M provided sensor measurement, timekeeping, data reduction, data/program storage and control functions. Data and programs were stored either in a nonvolatile Flash memory or RAM. A lithium battery backed up the RAM and real-time clock. The CR10X-2M also suspended execution when primary power (BPALK, PS100) dropped below 9.6 V, reducing the possibility of inaccurate measurements.

Leer más

Imágenes

Descripción detallada

The CR10X-2M stored up to 1,000,000 data points. The datalogger consisted of a CR10XM-2M Measurement and Control Module and black CR10X Wiring Panel.

The CR10X-2M provided sensor measurement, timekeeping, data reduction, data/program storage and control functions.  Data and programs were stored either in a nonvolatile Flash memory or RAM. A lithium battery backed up the RAM and real-time clock. The CR10X-2M also suspended execution when primary power (BPALK, PS100) dropped below 9.6 V, reducing the possibility of inaccurate measurements.

The CR10X-2M was removed from our pricing system on 19 April 2007.

Preguntas frecuentes

Número de FAQs relacionadas con CR10X-2M: 3

Expandir todoDesplegar todo

  1. The red and blue wire in differential channel 5 is a thermocouple. We ship the datalogger with this thermocouple so that users can work through sample program #2 in the "CR10X Measurement and Control Module Overview" section of the CR10X manual. Feel free to remove this temperature measurement sensor if it is not needed.

  2. A practical maximum is to connect one multiplexer per every two control terminals on the datalogger. Control terminals can be shared between multiplexers to increase the number of connected multiplexers. Sharing terminals, however, requires more complex wiring and programming. Users who would like to connect more than one multiplexer per every two control terminals are advised to contact a sales or support engineer at Campbell Scientific for assistance.

Compatibilidad

Use of the CR10X-2M within a Data Acquisition System

A typical field-based CR10X-2M system included:

  • CR10X-2M Measurement and Control Module and Wiring Panel with specified Operating System
  • Alkaline or Rechargeable Power Supply
  • Weatherproof Enclosure
  • Communications Peripheral(s)
  • Programming and Communications Software
  • Sensors

Especificaciones

  • Memory: up to 1,000,000 data points
  • Analog inputs: 12 single-ended or 6 differential, individually configured
  • Pulse counters: 2
  • Switched voltage excitations: 3
  • Control/digital ports: 8
  • Serial I/O port: 1
  • Scan rate: 64 Hz
  • Burst mode: 750 Hz
  • Analog volt. resolution: to 0.33 µV
  • A/D bits: 13
  • Programming: Edlog
  • Data Storage: Mixed Array, Table
  • Telecommunications: PakBus, Modbus, Alert

Descargas

CR10X OS v.1.23 (1.45 MB) 02-04-2010

Execution of this download installs the CR10X Operating System (Mixed-Array) on your computer.  

Note: The Device Configuration Utility is used to upload the included operating system to the datalogger.  Requires an SC32A or SC32B.


CR10X-TD OS v.1.15 (645 KB) 28-03-2006

Execution of this download installs the CR10X Table Data Operating System on your computer.  

Note: The Device Configuration Utility is used to upload the included operating system to the datalogger.  Requires an SC32A or SC32B.


CR10X-PB OS v.1.10 (647 KB) 28-03-2006

Execution of this download installs the CR10X PakBus Operating System on your computer.  

Note: The Device Configuration Utility is used to upload the included operating system to the datalogger.  Requires an SC32A or SC32B.


Device Configuration Utility v.2.33 (49.6 MB) 07-07-2025

A software utility used to download operating systems and set up Campbell Scientific hardware. Also will update PakBus Graph and the Network Planner if they have been installed previously by another Campbell Scientific software package.

Supported Operating Systems:

Windows 11 or 10 (Both 32 and 64 bit)

Historial revisiones