Cables de datos / SC32B
SC32B Interface RS-232 con aislamiento óptico (puerto CS I/O)

Resumen

The SC32B Optically Isolated Interface is used to connect the CS I/O port on a datalogger with the RS-232 port on a PC. This interface converts the RS-232 voltage levels of the computer to the CMOS levels of the datalogger. It also isolates the electrical system of the computer from the datalogger, thereby protecting against ground loop, normal static discharge, and noise.

Leer más

Ventajas y características

  • Conecta un PC al puerto CS I/O de un datalogger
  • Ayuda a proteger los componentes contra daños eléctricos
  • No requiere fuente de alimentación— alimentado por datalogger y PC
  • Se entrega con cables que se necesitan en la mayoría de los casos
  • Soporta velocidades de hasta 115 kbps

Imágenes

Right view
SC32B with included 10873 and SC12 cables (other items sold separately)

Descripción detallada

The SC32B, or another interface, is required for direct communications between a PC and a CR510, CR10X, or CR7 datalogger. For our CR800, CR850, CR1000, and CR1000X dataloggers, the SC32B is often used to provide optical isolation between the data logger and PC. Although the on-board RS-232 port of the CR3000, CR5000, or CR9000X dataloggers is isolated, the SC32B can be interfaced with their CS I/O port when a second RS-232 port is required in the application.

The SC32B is shipped with an SC12 (2 ft) cable for attachment to the data logger and a 10873 (6 ft) cable for attachment to the PC. Alternatively, an SC12R-6 (6 ft) cable (purchased separately) can be used instead of the standard SC12 when a longer cable is needed.

The SC32B can support RS-232 cable lengths of up to 50 feet; longer cable lengths are not recommended. The longer cable should be on the data logger side of the interface (CMOS logic levels) as opposed to the RS-232 side, which is typically more sensitive to drops in signal voltage levels.


Preguntas frecuentes

Número de FAQs relacionadas con SC32B: 15

Expandir todoDesplegar todo

  1. Because the SC-USB includes a processor, it costs more to manufacture than the SC32B.
  2. No. The SC32B cannot be used at the same time as an SDC device. The SC32B is a modem-enabled device and is not capable of concurrent communication.
  3. Yes. It ships with both the SC12 and 10873 serial cables. Usually, the SC12 is connected to the datalogger, and the 10873 is connected to the computer.
  4. Non-isolated interfaces (that is, connection to the RS-232 port with a standard serial cable connection) can cause ground offset errors in analog measurements using a system connected to a PC and powered by an ac source. The SC32B provides isolation that may be important when recording low-level, single-ended voltage measurements.

  5. No, because it would not work. The SC32B is used to do the following:

    • Convert datalogger logic levels (on the CS I/O port) to RS-232 levels 
    • Optically isolate the datalogger from the RS-232 peripheral 
  6. This is not necessarily an error associated with the SC32B. The message means that an attempt to check or set the clock on a mixed-array datalogger (CR10, CR21X, CR7X, CR10X, CR510, and CR23X) failed. There could be several reasons for this error.
  7. The SC929 has been functionally replaced by the SC32B. While the SC929 is still available, the SC32B has increased capability at a reduced cost. See the table for a comparison:

     

      SC929

      SC32B

      Optically Isolated

      No

      Yes

      Maximum Baud

      9600

      115200

      Current Draw

      8 mA

      Active < 200 µA

    Cables are an additional comparison point for these two products:

    • The SC929 cable directly connects the PC to the datalogger’s CS I/O port.
    • The SC32B interface typically uses the 10873 serial cable to connect to the PC and the SC12 cable to connect to the CS I/O port. Both of these cables are shipped with the SC32B.
  8. There are several differences:

    • The SC32A requires a 25-pin serial cable between the computer and interface. The SC32B, on the other hand, has DB9 connectors for both the datalogger and computer side.
    • The SC32B cannot be configured to pass serial printer or computer data.

    For comparisons, see the SC32A product page and the SC32B product page.

  9. The combination of the USB to serial (17394) and the SC32B is basically the same as the SC-USB. Both options enable communication between a computer and a data logger with a CS I/O port.


Especificaciones

Baud Rates Supported Up to 115 kbps
Power Drawn from the serial ports of the PC and data logger
Typical Current Drain
  • < 200 µA (quiescent)
  • ~15 mA (active)
Connections 9-pin RS-232 socket (female) port configured as DCE; 9-pin pin (male) port
Operating Temperature Range -25° to +50°C
Dimensions 4.1 x 2.3 x 7.6 cm (1.6 x 0.9 x 3.0 in.)
Weight 45.4 g (1.6 oz)

Compatibilidad

Nota: lo siguiente muestra información de compatibilidad notable. No es una lista de todos los productos compatibles.

Dataloggers

Producto Compatible Nota
CR1000 (retired)
CR1000X
CR200X (retired)
CR216X (retired)
CR3000 (retired)
CR5000 (retired)
CR6
CR800 (retired)
CR850 (retired)
CR9000X (retired)

Miscelaneo

Producto Compatible Nota
21X (retired)
CR10 (retired)
CR10X (retired)
CR23X (retired)
CR500 (retired)
CR510 (retired)
CR9000 (retired) The CR9000 requires a CR9080 PAM module.

Información de compatibilidad adicional

Data Logger Considerations

An interface such as the SC32B is required for direct communications between a PC and data loggers that only have a CS I/O port. For our CR800, CR850, and CR1000 dataloggers, the SC32B is often used to provide optical isolation between the data logger and PC. Although the on-board RS-232 port of the CR3000, CR5000, or CR9000X dataloggers is isolated, the SC32B can be interfaced with their CS I/O port when a second RS-232 port is required in the application.

Figura en

Common Accessory for the following products:
Replacement Part for the following products: