Services Available | |
---|---|
Repair | No |
Calibration | No |
Free Support | No |
The OBS-5+ monitors high sediment concentrations using an infrared laser and a proprietary dual photo-detection system (U.S. Patent No. 5,796,481). The probe transmits sediment concentration and depth to a PC via an RS-232 or RS-485 link. Data are also stored internally.
The OBS-5+ is ideal for monitoring dredging and site-remediation operations, determining dredge efficiency, providing data for sediment transport research, and supporting undersea mining and trenching.
(OBS® is a registered trademark of Campbell Scientific.)
Leer másThe OBS-5+ has a Windows GUI that enables the user to generate and store sediment calibration tables, log data, program logging/sampling schemes, and graphically display data. Using the Windows GUI, an operator can calibrate the OBS-5+ with sediments, change electronics gain to optimize resolution, create as many as 15 unique sediment lookup tables, and store those tables in FLASH memory for future use. Users can complete the entire calibration process without spreadsheet calculations and curve fitting.
Unlike single-detector systems such as the OBS-3+, which cannot measure suspended solids concentration (SSC) levels greater than about 10 g l-1 (mud) and 100 g l-1 (sand), the OBS-5+ uses multiple detectors. With these detectors and an embedded controller, the OBS-5+ extends the measurement range of the sensor by a factor of about ten.
The OBS-5+ projects a beam of near infrared (NIR) laser light into a water sample next to two photodetectors. Suspended particles scatter light from the beam onto the detectors and a microcontroller determines SSC from their photocurrents. Because the detectors are unequally spaced from the laser, the particle concentrations corresponding to the peak response are also unequal and after being calibrated with sediment, an OBS-5+ can measure and uniquely resolve sediment SSC values greater than the peaks in response.
The OBS-5+ has been used extensively to monitor dredging and mining operations in the US, EU, China, Vietnam, and Indonesia.
John Downing. 1998. Suspended Particle Concentration Monitor. U.S. Patent Number 5,796,481.
(OBS® is a registered trademark of Campbell Scientific.)
Connector | MCBH-8-FS, wet-pluggable |
Wetted Materials | 316 stainless steel, Delrin, and 20% GF polycarbonate |
Rango temperatura funcionamiento | 0° to 40°C |
Rango temperatura almacenamiento | -20° to +70°C |
Infrared Wavelength | 780 nm |
Scattering Angles | 105° to 165° (clean water) |
Drift over Time | < 30 ppm per month |
Drift over Temperature | < 200 ppm per °C |
Maximum Sampling Rate | 25 Hz |
Maximum Data Rate | 2 Hz |
Data Capacity | 8 MB |
Maximum Number of Data Lines | 200,000 |
Battery Capacity | 8 Ahr |
Maximum Battery Life | 3,000 h |
External Supply Voltage | 6 to 18 Vdc |
External Supply Current | 55 mA |
PC Interfaces | RS-232/115 kbps, RS-485/115 kbps |
Maximum Concentration Range |
|
Pressure Measurement Range | 0 to 10, 20, 50, 100, or 200 m |
Turbidity Measurement Range | 0.4 to 1,000 NTU |
Concentration Accuracy |
|
Pressure Accuracy | 0.5% of full scale |
Turbidity Accuracy | 1.5% of full scale |
Maximum Submersion Depth | 300 m (984 ft) |
Diameter | 6.0 cm (2.4 in.) |
Longitud | 38.0 cm (15 in.) |
Peso | 2.04 kg (4.5 lb) |
Submerged Weight | 1.02 kg (2.3 lb) |
Accuracy |
|
Sediment Concentration |
|
Pressure | 0.5% of full scale |
Turbidity | 1.5% of full scale |
Campbell Scientific offers a choice of field cables used to connect the OBS-5+ to a PC for system configuration. The cables differ in their length (see Ordering Info).
Utility for the OBS-5+ sensor.